1. Wide input voltage range 2:1, isolated regulated output 10W
2. Isolation voltage 1500VDC
3. Transfer efficiency up to 86%
4. Quick Start:100mS(Typ)
5. Operating temperature range :-40°C~+85°C
6. Small SIP package, metal case, low output ripple
7. International standard pin,direct installation of PCB board
8. Output short-circuit protection: continuous short circuit protection, automatic recovery
Input Characteristics
Item
Working conditions
Min.
Typ.
Max.
Unit
Input current(fully load/no-load)
12VDC Input Series
3.3V Output
-
714/25
733/42
5.0V Output
-
1067/25
1096/42
12.0V Output
-
845/25
867/42
15.0V Output
-
1003/25
1028/42
mA
24.0V Output
-
911/25
1015/42
24VDC Input Series
3.3V Output
-
357/13
366/21
5.0V Output
-
533/13
548/21
12.0V Output
-
423/13
434/21
15.0V Output
-
502/13
514/21
24.0V Output
-
455/13
508/21
48VDC Input Series
3.3V Output
-
179/7
183/11
5.0V Output
-
267/7
274/11
12.0V Output
-
212/7
217/11
15.0V Output
-
251/7
257/11
24.0V Output
-
228/7
148/11
110VDC Input Series
3.3V Output
-
78/3
80/2
5.0V Output
-
116/3
119/5
12.0V Output
-
109/3
111/5
15.0V Output
-
209/3
214/5
24.0V Output
-
105/3
107/5
Reflected Ripple Current
12VDC Input Series
--
60
--
mA
24VDC Input Series
--
40
--
48VDC Input Series
--
30
--
110VDC Input Series
--
20
--
Impulse voltage (Isec.max)
12VDC Input Series
-0.7
--
30
VDC
24VDC Input Series
-0.7
--
50
48VDC Input Series
-0.7
--
10
110VDC Input Series
-0.7
--
20
Start voltage
12VDC nominal input series, nominal input voltage
-
-
9
24VDC nominal input series, nominal input voltage
-
-
18
48VDC nominal input series, nominal input voltage
-
-
36
110VDC nominal input series, nominal input voltage
-
-
72
Input under-voltage protection
24VDC nominal input series, nominal input voltage
-
-
-
48VDC nominal input series, nominal input voltage
-
-
-
110VDC nominal input series, nominal input voltage
-
--
-
Start time
Nominal input voltage and constant resistance load
-
100
--
ms
Input filter type
PI Type
Hot plugged
Non-support
CNT(Ctrl)*
Module turned on
Ctrl dangling or TTL high level (3.5-12VDC)
Module turned off
Ctrl Connect to GND or low level (0-1.2VDC)
Input current at shutdown
-
0
1
mA
Note: * The voltage of the Ctrl control pin is relative to the input pin GND, this series of products does not have this function.
Output Characteristics
Project name
Working and testing condition
+V01
-V02
Min.
Typ.
Max.
Min.
Typ.
Max.
output load
load percentage
0%
-
100%
0%
-
100%
Output Voltage Accuracy
-
±1.0%
±2.0%
-
±2.0%
±3.0%
Linear adjustment rate
input voltage range
-
±2.0%
±0.5%
-
±1.5%
±2.0%
Load adjustment rate
20%~100% rate
load, balanced
--
±0.5%
±1.0%
-
±4.0%
±5.0%
Ripple & Noise
Pure resistive load, 20HMz bandwidth, peak-to-peak
--
50mVp-p
80mVp-p
-
50mVp-p
80mVp-p
Output voltage regulation
Input voltage range
-
No adjustment end
-
-
No adjustment endNo adjustment end
-
Output short circuit protection
Continuous short circuit protection, automatic recovery
Notes: Ripple and Noise Test Methods Twisted Pair Test Method
Note:
1、The above is only a list of typical products. If you need products beyond the list, please contact our sales. 2、The maximum capacitive load indicates the maximum capacitive load that + VO or - vo can be connected to,If the value is exceeded, the product will not start normally..
Typical Application Circuits
EMC parameter recommendation
Component No.
Function
Recommended value
FMSE
Slow blowing fuse, selected according to the actual input current of the customer
CY1 safety capacitor
1nF/250Vac
Notes:More details please feel free to contact hi-link team.
Our website uses essential Cookie to help us ensure that it is working as expected, and uses optional analytics Cookie to offer you a better browsing experience. To find out more, read our Cookie Notice.