1. Wide input voltage range 4:1, isolated regulated output 40W
2. Isolation voltage 1500VDC
3. Transfer efficiency up to 91%
4. Quick Start:1mS(Typ)
5. Operating temperature range :-40°C~+85°C
6. Small SIP package, metal case, low output ripple
7. International standard pin,direct installation of PCB board
8. Output short-circuit protection: continuous short circuit protection, automatic recovery
Enviroment Condition
Project name
Qualification
Unit
Notes
Working enviroment temperature
-40—+85
℃
Storage temperture
-40—+125 ℃
℃
Relative humidity
5—95
%
Heat dissipation mode
natural cooling
Atmospheric pressure
80—106 Kpa
Kpa
Ripple & Noise
50/80(max)
Mvp-p
Input Characteristics
Item
Working conditions
Min.
Typ.
Max.
Unit
Input voltage range(fully loaded/unloaded)
24VDC Input Series
12V
-
1851/2
1893/3
15v
-
1831/2
1872/3
24v
-
1831/2
1872/3
48VDC Input Series
5V
-
946/1
968/2
9V
-
936/1
957/2
12V
-
936/1
957/2
15V
-
925/1
946/2
24V
-
915/1
936/2
110VDC Input Series
5V
-
413/0.5
422/1
9V
-
404/0.5
413/1
12V
-
404/0.5
413/1
15V
-
399/0.5
408/1
24V
-
399/0.5
408/1
Reflected Ripple Current
nominal Input Series
--
40
--
mA
Impulse voltage (Isec.max)
24VDC Input Series
-0.7
--
50
VDC
48VDC Input Series
-0.7
--
100
110VDC Input Series
-0.7
--
180
Start voltage
24VDC nominal input series, nominal input voltage
-
-
9
48VDC nominal input series, nominal input voltage
-
-
18
110VDC nominal input series, nominal input voltage
-
-
40
Input undervoltage protection
24VDC nominal input series, nominal input voltage
5.5
8.0
-
48VDC nominal input series, nominal input voltage
12
15.5
-
110VDC nominal input series, nominal input voltage
30
34
-
Input filter type
PI filter type
Hot plugged
Non-support
Output Characteristics
Project name
Working and testing condition
+V01
-V02
Min.
Typ.
Max.
Min.
Typ.
Max.
output load
load percentage
0%
-
100%
0%
-
100%
Output Voltage Accuracy
-
±1.0%
±2.0%
-
±2.0%
±3.0%
Linear adjustment rate
input voltage range
-
±0.2%
±0.5%
-
±1.5%
±2.0%
Load adjustment rate
20%~100% rate
load, balanced
--
±0.5%
±1.0%
-
±4.0%
±5.0%
Ripple & Noise
Pure resistive load, 20HMz bandwidth, peak-to-peak
--
50mVp-p
80mVp-p
-
50mVp-p
80mVp-p
Output voltage regulation
Input voltage range
-
No adjustment end
-
-
No adjustment endNo adjustment end
-
Output short circuit protection
Continuous short circuit protection, automatic recovery
Notes: Ripple and Noise Test Methods Twisted Pair Test Method
Note:
1、The above is only a list of typical products. If you need products beyond the list, please contact our sales. 2、The maximum capacitive load indicates the maximum capacitive load that + VO or - vo can be connected to,If the value is exceeded, the product will not start normally..
Typical Application Circuits
EMC parameter recommendation
Component No.
Function
Recommended value
FMSE
selected according to the actual input current of the customer
CY1 safety capacitor
1nF/250Vac
Notes:More details please feel free to contact hi-link team.